Valve function |
5/2 bistable
|
Actuation type |
Electrical
|
Build.width [mm] |
32
|
Normal nominal flow [l/min] |
1.000
|
Operating pressure [bar] |
1.5 to 8
|
Construction set up |
Plate seat
|
Certified awarding point |
DNVGL-TAA000011J
|
Exhaust function |
Can be throttled
|
Sealing principle |
Soft
|
installation position |
arbitrary
|
Complies to standard |
VDI/VDE 3845 (NAMUR)
|
Hand assist actuation |
Ratcheting, tentative
|
Control type |
pilot operated
|
Control air supply |
Internal
|
Flow direction |
Not reversible
|
Überdeckung |
negative Überdeckung
|
Signal condition display |
With Accessories
|
b-value |
0.24
|
C-value [l/sbar] |
4,60
|
Power-on time |
100 %
|
Coil characteristic value |
See solenoid coil, order separately
|
Operating medium |
Compressed air to ISO 8573-1:2010 [7:4:4]
|
Information about operating and control medium |
Oiled operation possible (required in further operations)
|
Corrosion resistant class KBK |
2 - moderate corrosion stress
|
Medium temperature [°C] |
-20 to 60
|
ambient temperature [°C] |
-20 to 60
|
Product weight [g] |
445
|
Fastening type |
With throughway bores
|
Breathing opening connection |
Not recorded
|
Pneumatic connection 1 |
G1/4
|
Pneumatic connection 2 |
NAMUR wiring diagram
|
Pneumatic connection 3 |
G1/4
|
Pneumatic connection 4 |
NAMUR wiring diagram
|
Pneumatic connection 5 |
G1/4
|
Material information |
RoHs compliant
|
Seals material |
NBR
|
Housing material |
Aluminium wrought alloy
|
Screws material |
High-alloyed stainless steels
|
Shifting time um [ms] |
16
|